EneltPro UPS of PRO RT S(H) series, 1кVA - 3 кVA
- Possibility of use, both horizontally (in a rack) and in a vertical position
- LCD display screen - it is possible to rotate the screen 90 degrees.
- Double conversion of electricity
- Fully digital control (DSP)
- Output power factor: 0.8
- Economy mode of operation (ECO)
- Wide input voltage range
- Has a self-test function when the UPS is running.
- Cold start.
- Multifunctional protection
- Adjustable bypass.
- Phase sequence control.
- Completing with batteries (optional): 1K-24V, 2K-48V, 3K-72V
- Intelligent control
- Smart slot (optional): USB / SNMP / dry contact plate
Model | PRO S RT 1KVA | PRO H RT 1KVA | PRO S RT 2KVA | PRO H RT 2KVA | PRO S RT 3KVA | PRO H RT 3KVA | ||
Power (VA) | 1,000VA/800W | 2,000VA/1,600W | 3,000VA/2,400W | |||||
Input | Phase Rated voltage Voltage range Frequency range Power factor ECO Range Bypass voltage range Harmonic current Phase Rated voltage | 1 phase and grounded | ||||||
220VAC | ||||||||
115VAC-295VAC | ||||||||
45~55Hz±0.5Hz or 55~65Hz±0.5Hz automatic detection | ||||||||
≥0.98 | ||||||||
200VAC-240VAC | ||||||||
186VAC-252VAC | ||||||||
≤7%(100% nonlinear load) | ||||||||
Output | 1 phase and grounded | |||||||
200/208/220/230/240VAC (option) | ||||||||
Power factor Voltage accuracy Output frequency Useful mode Battery mode Amplitude factor (crest factor) | 0.8 | |||||||
±2% | ||||||||
| ||||||||
(50/60±0.2%)Hz | ||||||||
3:1 | ||||||||
Switching time | (Network ← → battery) = 0ms (Network ← → battery) <4ms (Network → ECO (eco mode)) <10ms (Battery → ECO (eco mode)) <10ms 108% ± 5% <load≤150% ± 5% - more than 30s, then shutdown alarm 150% ± 5% <load <200% ± 5% -more than 300ms, shutdown and alarm 108% ± 5% <load≤150% ± 5% - more than 30s, then transfer to bypass and alarm on. 150% ± 5% <load <200% ± 5% - more than 300ms then transfer to bypass and alarm. | |||||||
Overload capability | Battery mode | |||||||
Power mode | ||||||||
Efficiency | Battery mode | 87% | 88% | 88% | ||||
Power mode | 85% | 85% | 85% | |||||
Factor of non-linear distortion THD | ≤3% (100% linear load) ≤5% (100% non-linear load) | |||||||
ECO (Eco mode) Efficiency | ≥94% | |||||||
Battery | Electrical voltage Battery configuration Type Reservation time Charging current (A) | 24VDC | 24VDC | 48VDC | 48VDC | 72VDC | 72VDC | |
2x12V/9AH |
| 4X12V/9AH |
| 6X12V/9AH |
| |||
12V / 9AH Lead-acid maintenance-free battery (standard) Full load ≥5min (typical), or depending on battery capacity | ||||||||
1A | 7A | 1A | 7A | 1A | 7A | |||
Communication interface | RS232 port, (USB port, USB card, SNMP card, dry contact card option) | |||||||
Work medium | Temperature Humidity Storage temperature Height Dimensions (W × D × H) (mm) Weight (Kg) | 0℃~40℃ | ||||||
0~95% (without condensation) | ||||||||
-25℃~55℃ | ||||||||
< 1,500m | ||||||||
Others | 440×380×86.5 | 440×520×131 | ||||||
12/14.5 | 7/9.5 | 21.5/24.5 | 11.5/14.3 | 26/28.8 | 11.7/14.5 |